DELTA
Flo - Flow Analysis Data Systems
DELTA Flo is a data system for capturing signals from up to three
chemistries from a segmented flow or flow injection analyzer.
Optionally, you may choose to control one of the supported auto-samplers. If
so, then alignment between the method sample sequence and the delivered peak
train is guaranteed.
Take the Delta Flo test drive by downloading the file from our
downloads page and following the step by step
procedures in the test drive document. In a mere half hour you'll discover the
following features ...
During a data collection run you may...
 |
Alter the viewing width of the displayed trace
history from one to thirty minutes. |
 |
Alter the viewing scale individually for each
trace. |
 |
View the run time report of results on screen as
the peaks are detected and analyzed. |
 |
Edit methods and reprocess previously collected
data. |
Delta Flo 4 sports a completely new data file format which is essentially a
file system within a file. The following information is saved in sub-files
within a data file.
 |
The actual collected trace data. |
 |
A table of peak positions, heights etc.
collected during the run. |
 |
A copy of the run time report. |
 |
A copy of the post run report. |
This means after a run has completed, a data file may be opened and …
 |
Run time and post run reports may be view on
screen and printed without requiring reprocessing or access to the original
(data collection) method. |
 |
The data files contain all of trace and other
data (for all channels) as well as the reports in a single file. This makes
them ideal for archiving on backup media such as CDROM, avoiding the need to
store paper reports or chart recorder traces. |
Reprocessing is performed in a completely separate window which allows ..
 |
Reprocessing allows peak crest positions to be
manually moved by dragging with the mouse, the data may then be reprocessed
(this takes 2-3 seconds even for 500 minute runs). This re-generates the run
time and post run reports as well as repopulating the export table in the
method (a method is requited for re-processing) |
 |
The run time reports and post run reports may be
viewed / re-printed in the re-processing window. |
 |
Method settings may be altered and the data
re-processed in seconds in order to fine tune methods. |
 |
The trace review shows all trace markers and
allows unlimited zooming and panning for closer inspection and accurate
re-location of peak markers. |
So take the test drive now. It only takes half an
hour, and ... a picture really does paint a thousand words !
|